16 BuildingWrench guides

❄️ HVAC

Safe first checks, airflow, condensate, thermostats, WSHP, RTU, and VRF troubleshooting patterns.

Choose the next check

Follow the condensate path: drain and trap, pump and discharge, then the high-water safety. Correct the water problem before restarting equipment.

Routine facility fix

HVAC Condensate Drain Clogged: How to Clear a Routine Blockage

A clogged condensate drain can shut cooling down, overflow a pan, stain ceilings, and trip a float switch. Accessible drains can often be cleared with safe mechanical cleaning, flushing, or a wet/dry vacuum while leaving the safety devices intact.

Skill: Beginner
Routine diagnosis

Thermostat Says Cooling but Nothing Happens: Commercial HVAC Checks

When a thermostat shows a cooling call but the room is still warm, divide the problem into controls, airflow, and equipment response. Entry-level maintenance can safely verify schedules, setpoints, fan operation, filters, condensate safeties, and obvious alarms before escalating.

Skill: Beginner
Diagnose then escalate

VRF One Zone Not Cooling: How to Narrow Down the Problem

When one VRF indoor unit is warm but the rest of the system is cooling, the failure pattern is the biggest clue. Start with local controls, mode conflicts, airflow, sensors, branch components, and fault codes before assuming a system-wide refrigerant problem.

Skill: Intermediate
Diagnose then escalate

Water-Source Heat Pump Not Cooling: Facilities Troubleshooting Checklist

For a water-source heat pump that runs but does not cool, verify thermostat demand, airflow, filter condition, loop-water availability, condensate safeties, and whether neighboring units are affected. Refrigerant and internal electrical diagnosis should be escalated.

Skill: Beginner–Intermediate
Diagnose then escalate

RTU Fan Runs but No Cold Air: What Maintenance Should Check

If the rooftop fan runs but supply air is not cooling, the airflow circuit is alive but the cooling stage may be locked out, not commanded, or unable to operate. Gather evidence before calling service.

Skill: Beginner
Routine facility fix

Thermostat Temperature Reading Is Wrong: How to Check It

A thermostat that reads several degrees off may be influenced by sunlight, wall temperature, drafts, local heat sources, remote-sensor configuration, or calibration. Verify with a good thermometer first.

Skill: Beginner
Routine facility fix

Weak HVAC Airflow in One Room: Easy Things to Check

One room with weak airflow usually points to a local restriction or control issue: blocked grille, closed damper, crushed flex duct, terminal-unit problem, or furniture obstruction.

Skill: Beginner
Routine facility fix

RTU Economizer Damper Stuck Open: Signs and Safe Checks

An economizer stuck open can make a building humid, hot, cold, or pressurized. Maintenance can compare commanded versus visible damper position and check for obvious mechanical obstruction.

Skill: Beginner
Routine facility fix

One Room Is Too Humid: Commercial HVAC Troubleshooting

High humidity in one room can come from excess outdoor air, low cooling runtime, exhaust imbalance, moisture sources, sensor error, or airflow problems. Measure temperature and relative humidity before changing setpoints.

Skill: Beginner